US verification — FHWA and ACI examples, reproduced
Four published US strut-and-tie design examples rebuilt in AStrutTie. The values that must match — member forces and reactions from the same geometry and loads — are compared with the source, line by line. Each example opens in the app in US units.
- 4published US examples
- 29/29must-match values within source rounding
- 0unsafe-side differences
How to read the tables
- Source = the number printed in the example (kip; tension +, compression −; reactions upward +). AStrutTie = the app's analysis of the same model, from the regression snapshot of the release you are using.
- Match = within the source's rounding: 0.5% of the value + 0.15 kip. If any one value drifts, the release gate (us_examples_gate) blocks the release.
- Strength and anchorage verdicts are AStrutTie's checks under the current codes (ACI 318-25 or AASHTO LRFD 10th edition). Where they differ from the source, the reason is listed — including the source's own deficiencies.
FHWA-NHI-17-071 Design Example 1 — Simply supported deep beam
Source: FHWA-NHI-17-071, Design Example 1, pp. 1-1–1-36 — AASHTO LRFD 8th ed. (2017)
Member forces of the source's strut-and-tie model (kip)
| Item | Source (kip) | AStrutTie (kip) | Difference | Result |
|---|---|---|---|---|
| AB | 506.3 | 506.3 | 0.0 | Match |
| BC | 1,012.5 | 1,012.5 | 0.0 | Match |
| BD | 600.0 | 600.0 | 0.0 | Match |
| AD | -785.0 | -785.0 | 0.0 | Match |
| BE | -785.0 | -785.0 | 0.0 | Match |
| CF | -1,176.9 | -1,176.9 | 0.0 | Match |
| DE | -506.2 | -506.2 | 0.0 | Match |
| EF | -1,012.5 | -1,012.5 | 0.0 | Match |
Source verdict: The top strut EF fails at the back face of its CCC nodes; the source adds compression bars to it. Every other check passes.
AStrutTie verdict: 10 strength checks pass · NG: B, E, EF, F · Anchorage: AB NG · BC NG
Where AStrutTie differs from the source, and why
- Strut EF and nodes E and F fail in AStrutTie too — the same deficiency the source finds. AStrutTie does not model strut reinforcement, so the NG stays.
- Tie BD sits just under 1.0 because AStrutTie takes bar area from the nominal diameter (#5 = 0.307 in²), 1% below the ASTM area the source uses.
- Smeared node B is checked by AStrutTie but not by the source.
- The source uses AASHTO LRFD 8th edition; AStrutTie checks the 10th edition (2024). Member forces do not depend on the edition; hooked-bar anchorage does (AB · BC anchorage NG, as in the source's short hook).
In the app: start screen → Examples → US verification examples → Simply supported deep beam. The comparison table opens from the example card.
FHWA-NHI-17-071 Design Example 4 — Drilled-shaft footing — 4 shafts (3D)
Source: FHWA-NHI-17-071, Design Example 4, pp. 4-4–4-37 — AASHTO LRFD 8th ed. (2017)
Column node loads and shaft reactions (kip, upward +)
| Item | Source (kip) | AStrutTie (kip) | Difference | Result |
|---|---|---|---|---|
| F_A | -1,763.6 | -1,763.7 | -0.1 | Match |
| F_D | -1,763.6 | -1,763.7 | -0.1 | Match |
| F_B | 339.1 | 339.2 | 0.1 | Match |
| F_C | 339.1 | 339.2 | 0.1 | Match |
| R (E) | 1,165.0 | 1,165.0 | 0.0 | Match |
| R (F) | 259.5 | 259.5 | 0.0 | Match |
| R (G) | 259.5 | 259.5 | 0.0 | Match |
| R (H) | 1,165.0 | 1,165.0 | 0.0 | Match |
Source verdict: Every strut, tie and node check passes with 12-#11 bottom ties, 6-#11 column ties and a 3-#11 top mat.
AStrutTie verdict: 29 strength checks pass · NG: b3, c2, c3, m22, m24, m5, p2 · Anchorage: m13 OK · m14 OK · m15 OK · m16 OK · m17 OK
Where AStrutTie differs from the source, and why
- Column node loads and shaft reactions match the source. The truss between them is AStrutTie's automatic 3D layout, not the source's hand-drawn one, so individual members carry different forces.
- The largest bottom tie in AStrutTie is higher than the source's FG (conservative side). Some struts and nodes that the automatic layout loads harder than the source show NG.
- The column is taken square, 7.5 ft (source 7.5 × 6.25 ft), with the source's linear-elastic stress block, so the four column node loads are the source's.
In the app: start screen → Examples → US verification examples → Drilled-shaft footing — 4 shafts (3D). The comparison table opens from the example card.
ACI SP-273 Example 1 — Hammerhead bent cap
Source: ACI SP-273, Example 1, pp. 1–16 — ACI 318-08 Appendix A
Member forces of the source's Model 1 (kip)
| Item | Source (kip) | AStrutTie (kip) | Difference | Result |
|---|---|---|---|---|
| AB | 1,083 | 1,082.8 | -0.2 | Match |
| BC | 802 | 801.6 | -0.4 | Match |
| CD | 147 | 146.9 | -0.1 | Match |
| AE | -1,289 | -1,289.4 | -0.4 | Match |
| BE | -489 | -489.0 | 0.0 | Match |
| CE | -789 | -789.4 | -0.4 | Match |
| DF | -178 | -177.7 | 0.3 | Match |
| CF | 441 | 441.1 | 0.1 | Match |
| EF | -147 | -146.9 | 0.1 | Match |
Source verdict: Every strength check passes under ACI 318-08, with hooked #11 ties at both tips.
AStrutTie verdict: all 15 strength checks pass · Anchorage: AB OK · CD OK
Where AStrutTie differs from the source, and why
- Every strength and anchorage check passes in AStrutTie as well.
- The hooked #11 ties pass under ACI 318-25, but the required hook length is about twice the source's: the hook equation was reworked in ACI 318-19.
- Interior struts keep βs = 0.75 only with the 0.0025 distributed grid of §23.5; the source's grid (0.0021) does not meet the newer rule.
- The source rounds member forces to 1 kip; the AStrutTie values are shown to 0.1 kip.
In the app: start screen → Examples → US verification examples → Hammerhead bent cap. The comparison table opens from the example card.
ACI SP-208 Example 3.1 — Column corbel
Source: ACI SP-208, Example 3.1, pp. 105–115 — ACI 318-02 Appendix A
Member forces of the source's model (kip)
| Item | Source (kip) | AStrutTie (kip) | Difference | Result |
|---|---|---|---|---|
| CB | 34.8 | 34.7 | -0.1 | Match |
| CD | -60.9 | -60.9 | 0.0 | Match |
| DD′ | -111.0 | -110.7 | 0.3 | Match |
| DA | 11.2 | 11.2 | 0.0 | Match |
Source verdict: Every check passes; the strut along the column face is sized exactly to the node limit, and tie CB is welded to a steel angle.
AStrutTie verdict: 13 strength checks pass · NG: n3, n4 · Anchorage: T1 NG
Where AStrutTie differs from the source, and why
- Nodes D and D′ show a safety factor of 0.9996 (NG by 0.04%): the source rounds the required strut width (3.101 in) down to the node limit (3.10 in).
- The source welds tie CB to a steel angle. AStrutTie checks straight, hooked or headed ends only, so CB is modeled as headed — and that anchorage fails as modeled.
In the app: start screen → Examples → US verification examples → Column corbel. The comparison table opens from the example card.
Verification documents
- Verification manual (English, printable)
- ACI 318-19 Chapter 23 guide — what AStrutTie checks
- AASHTO LRFD 5.8.2 guide — what AStrutTie checks
- How every release is verified
More US examples
These write-ups solve further published examples in AStrutTie. They are not yet in the reproduction pack above.
Next in the pack: TxDOT/CTR 5-5253-01 and ADOT SPR-782 examples, added in the same form once the published values are on file.
Only problem data, published results and page numbers are taken from the sources; figures and text are not reproduced. Every model and check on this page was run in AStrutTie.