Verification

US verification — FHWA and ACI examples, reproduced

Four published US strut-and-tie design examples rebuilt in AStrutTie. The values that must match — member forces and reactions from the same geometry and loads — are compared with the source, line by line. Each example opens in the app in US units.

  • 4published US examples
  • 29/29must-match values within source rounding
  • 0unsafe-side differences

How to read the tables

  • Source = the number printed in the example (kip; tension +, compression −; reactions upward +). AStrutTie = the app's analysis of the same model, from the regression snapshot of the release you are using.
  • Match = within the source's rounding: 0.5% of the value + 0.15 kip. If any one value drifts, the release gate (us_examples_gate) blocks the release.
  • Strength and anchorage verdicts are AStrutTie's checks under the current codes (ACI 318-25 or AASHTO LRFD 10th edition). Where they differ from the source, the reason is listed — including the source's own deficiencies.

FHWA-NHI-17-071 Design Example 1 — Simply supported deep beam

Source: FHWA-NHI-17-071, Design Example 1, pp. 1-1–1-36 — AASHTO LRFD 8th ed. (2017)

Member forces of the source's strut-and-tie model (kip)

ItemSource (kip)AStrutTie (kip)DifferenceResult
AB506.3506.30.0Match
BC1,012.51,012.50.0Match
BD600.0600.00.0Match
AD-785.0-785.00.0Match
BE-785.0-785.00.0Match
CF-1,176.9-1,176.90.0Match
DE-506.2-506.20.0Match
EF-1,012.5-1,012.50.0Match

Source verdict: The top strut EF fails at the back face of its CCC nodes; the source adds compression bars to it. Every other check passes.

AStrutTie verdict: 10 strength checks pass · NG: B, E, EF, F · Anchorage: AB NG · BC NG

Where AStrutTie differs from the source, and why

  • Strut EF and nodes E and F fail in AStrutTie too — the same deficiency the source finds. AStrutTie does not model strut reinforcement, so the NG stays.
  • Tie BD sits just under 1.0 because AStrutTie takes bar area from the nominal diameter (#5 = 0.307 in²), 1% below the ASTM area the source uses.
  • Smeared node B is checked by AStrutTie but not by the source.
  • The source uses AASHTO LRFD 8th edition; AStrutTie checks the 10th edition (2024). Member forces do not depend on the edition; hooked-bar anchorage does (AB · BC anchorage NG, as in the source's short hook).

In the app: start screen → Examples → US verification examples → Simply supported deep beam. The comparison table opens from the example card.

Scope sheet for this code (AASHTO LRFD)

FHWA-NHI-17-071 Design Example 4 — Drilled-shaft footing — 4 shafts (3D)

Source: FHWA-NHI-17-071, Design Example 4, pp. 4-4–4-37 — AASHTO LRFD 8th ed. (2017)

Column node loads and shaft reactions (kip, upward +)

ItemSource (kip)AStrutTie (kip)DifferenceResult
F_A-1,763.6-1,763.7-0.1Match
F_D-1,763.6-1,763.7-0.1Match
F_B339.1339.20.1Match
F_C339.1339.20.1Match
R (E)1,165.01,165.00.0Match
R (F)259.5259.50.0Match
R (G)259.5259.50.0Match
R (H)1,165.01,165.00.0Match

Source verdict: Every strut, tie and node check passes with 12-#11 bottom ties, 6-#11 column ties and a 3-#11 top mat.

AStrutTie verdict: 29 strength checks pass · NG: b3, c2, c3, m22, m24, m5, p2 · Anchorage: m13 OK · m14 OK · m15 OK · m16 OK · m17 OK

Where AStrutTie differs from the source, and why

  • Column node loads and shaft reactions match the source. The truss between them is AStrutTie's automatic 3D layout, not the source's hand-drawn one, so individual members carry different forces.
  • The largest bottom tie in AStrutTie is higher than the source's FG (conservative side). Some struts and nodes that the automatic layout loads harder than the source show NG.
  • The column is taken square, 7.5 ft (source 7.5 × 6.25 ft), with the source's linear-elastic stress block, so the four column node loads are the source's.

In the app: start screen → Examples → US verification examples → Drilled-shaft footing — 4 shafts (3D). The comparison table opens from the example card.

Scope sheet for this code (AASHTO LRFD)

ACI SP-273 Example 1 — Hammerhead bent cap

Source: ACI SP-273, Example 1, pp. 1–16 — ACI 318-08 Appendix A

Member forces of the source's Model 1 (kip)

ItemSource (kip)AStrutTie (kip)DifferenceResult
AB1,0831,082.8-0.2Match
BC802801.6-0.4Match
CD147146.9-0.1Match
AE-1,289-1,289.4-0.4Match
BE-489-489.00.0Match
CE-789-789.4-0.4Match
DF-178-177.70.3Match
CF441441.10.1Match
EF-147-146.90.1Match

Source verdict: Every strength check passes under ACI 318-08, with hooked #11 ties at both tips.

AStrutTie verdict: all 15 strength checks pass · Anchorage: AB OK · CD OK

Where AStrutTie differs from the source, and why

  • Every strength and anchorage check passes in AStrutTie as well.
  • The hooked #11 ties pass under ACI 318-25, but the required hook length is about twice the source's: the hook equation was reworked in ACI 318-19.
  • Interior struts keep βs = 0.75 only with the 0.0025 distributed grid of §23.5; the source's grid (0.0021) does not meet the newer rule.
  • The source rounds member forces to 1 kip; the AStrutTie values are shown to 0.1 kip.

In the app: start screen → Examples → US verification examples → Hammerhead bent cap. The comparison table opens from the example card.

Scope sheet for this code (ACI 318)

ACI SP-208 Example 3.1 — Column corbel

Source: ACI SP-208, Example 3.1, pp. 105–115 — ACI 318-02 Appendix A

Member forces of the source's model (kip)

ItemSource (kip)AStrutTie (kip)DifferenceResult
CB34.834.7-0.1Match
CD-60.9-60.90.0Match
DD′-111.0-110.70.3Match
DA11.211.20.0Match

Source verdict: Every check passes; the strut along the column face is sized exactly to the node limit, and tie CB is welded to a steel angle.

AStrutTie verdict: 13 strength checks pass · NG: n3, n4 · Anchorage: T1 NG

Where AStrutTie differs from the source, and why

  • Nodes D and D′ show a safety factor of 0.9996 (NG by 0.04%): the source rounds the required strut width (3.101 in) down to the node limit (3.10 in).
  • The source welds tie CB to a steel angle. AStrutTie checks straight, hooked or headed ends only, so CB is modeled as headed — and that anchorage fails as modeled.

In the app: start screen → Examples → US verification examples → Column corbel. The comparison table opens from the example card.

Scope sheet for this code (ACI 318)

Verification documents

More US examples

These write-ups solve further published examples in AStrutTie. They are not yet in the reproduction pack above.

Next in the pack: TxDOT/CTR 5-5253-01 and ADOT SPR-782 examples, added in the same form once the published values are on file.

Only problem data, published results and page numbers are taken from the sources; figures and text are not reproduced. Every model and check on this page was run in AStrutTie.